| Temperature | Convert a temperature to sensor output value |
| Value: Resistance/EMF/Voltage | Convert from a sensor output value to temperature |
| Curve: Min temp. | Limit the range for the curve, when this field is empty a default value is used |
| Curve: Max temp. | Limit the range for the curve, when this field is empty a default value is used |
| Alpha etc: R (0 °C) | Resistance of sensor at 0 °C |
| Alpha etc: Alpha/Delta/Beta | Parameters for a PT sensor, use Default button to fill in value for PT100 |
| ABC: R (0 °C) | Resistance of sensor at 0 °C |
| ABC: A/B/C | Parameters for a PT sensor, use Default button to fill in value for PT100 |
| Measurements: R (0 °C) | Resistance of sensor at 0 °C |
| Measurements: R (100 °C) | Resistance of sensor at 100 °C, use Default button to fill in value for PT100 |
| Measurements: R (260 °C) | Resistance of sensor at 260 °C, use Default button to fill in value for PT100 |
| B(eta): R (25 °C) | The specified resistance of the NTC |
| B(eta): Beta | The specified beta of the NTC |
| B(eta): Tol (%) | Specified tolerance for resistance and beta |
| Tempco: R (25 °C) | The specified resistance of the NTC |
| Tempco: Tempco (%/K) | The specified temperature coefficient of the NTC |
| Measurements: R1 at temp | First measured checkpoint |
| Measurements: R2 at temp | Second measured checkpoint |
| Divider input voltage | Supply voltage to the divider |
| Divider resistor | Resistor used in the divider. |
| Initial resistance | Initial resistance of the copper wire |
| Initial temperature | Initial temperature of the copper wire |
| Resistance | Resistance of sensor at specified temperature |
| EMF | Voltage at specified temperature |
| Voltage | Voltage at specified temperature |
| Delta | Slope on curve, specified in multiple ways |
| Temperature range | Temperature range for this kind of sensor, a actual sensor might be more limited |
| Resistance range | Resistance change from min. to max. temperature |
| EMF range | Voltage change within specied temperature range |
| Standards | What standards are used for this kind of sensors |
| Class A | Tolerance according to standard class A specificactions at specified temperature |
| Class B | Tolerance according to standard class B specificactions at specified temperature |
| Callendar-Van Dusen constants | Constants used to specify a PT sensor curve with |
| Reference junction 0 °C with ITS-90 calibration | A reminder that output from all "Type ?" thermo sensors are relative to 0 °C |